This family uses DSP provides a range of input signal processingand sophisticated internal and external monitoring for precision set-up and control -including complete system-wide management of thermal parameters -critical to reliable performance.
Communication with the amplifier is available through a real-time ADCI controller to allow users quickly analyze operational and fault status.
Each amplifier may be configured in multiple modes for specific load or test conditions via digital programming.
All units may be configured with matching power supplies and additional capacitance for reliable power delivery.
- High Performance
- Advanced Power Management
- Air or Liquid-Cooled Operation
- Digital Control Interface
Models 281/282 and C700
Model | Output Current | Pulse Output (A) Duration ON(ms)/OFF(ms) |
|||||
---|---|---|---|---|---|---|---|
+/-DC | Sine Wave | Triangle Wave | |||||
Vmax- | Adc/Arms | Apeak | Apeak | 500/500 | 100/100 | Imax | |
C700 | 700 | 212 | 300 | 367 | 220 | 300 | 500 |
282† | 675 | 250 | 354 | 433 | 325 | 350 | 500 |
281† | 675 | 360 | 509 | 624 | 450 | 500 | 850* |